ORLUTI

125B

Slim sightlines for mild climates.

Loading 3D explorer…

Demonstration assembly with semantic components — final Orluti extrusion geometry replaces this model via the documented GLB pipeline. Values marked ‡ await test-report confirmation.

Overview

System 125B carries Orluti's fabrication standards into a non-thermally-broken profile for mild climates, interior partitions, and value-driven scopes. The sightlines stay slim, the rollers stay stainless, and the finish options match the rest of the line — at a lighter cost per opening.

Value

Lighter profile, same discipline

Non-thermal-break extrusion machined and glazed to the same tolerances.

Use

Mild climates & interiors

Patios, pool houses, interior partitions, and temperate zones.

Line

Slim sightlines

Keeps the narrow-frame look of the premium systems.

Configurations

O = fixed panel · X = sliding panel, read from exterior. Pocketing versions conceal panels fully within the wall.

OX
One fixed, one slider

The essential value configuration.

XX
Both panels slide

Open from either side.

Profile & cross-sections

Photographed from production extrusions
System 125B corner section sample
Corner section · 125B-01
System 125B profile detail sample
Profile detail · 125B-02

Hardware

  • Stainless rollers

    Sealed stainless rollers sized to panel weight.

  • Two-point lock

    Positive latching with anti-lift pins. [CONFIRM LOCK SPEC]

Glazing

  • Double insulated glazing

    Insulated glazing units with Low-E coatings for mild-climate efficiency. [CONFIRM IGU MAKEUP]

  • Single glazing

    Tempered monolithic glass for interior partitions and unconditioned spaces.

Finishes

  • Matte Black
    powder coat
  • Bronze Anodized
    anodized
  • Champagne
    anodized
  • Silver Anodized
    anodized
  • Custom RAL
    custom

Specifications

System

Frame depth
5" (125 mm)
Thermal break
None — non-thermal profile
Max panel
440 lb · 9 ft tall

Performance

U-factor
0.55 representative

‡ Representative values pending confirmation against Orluti test reports — final performance depends on configuration and glazing.

Documents

Specification sheet
PDF · Issued per system with current tested values.
Request ↓
CAD section details — head, jamb, sill
DWG / DXF
Request ↓
Installation manual
PDF
Request ↓
Structural & thermal test reports
PDF · Provided per configuration with the engineered quote.
Request ↓

Documents are issued per system with current tested values — request routes through the quote form so an engineer can match the right revision to your project.

Spec the 125B into
your next project.

Schedules · plans · DWGs accepted